LogisimRevisited

Circuits / Combinational

Bus Contention / Short-Circuit Diagnostic

Easy

Demonstrates how connecting two opposing gate outputs directly onto one wire causes a red Error (E) state that the AI Signal Prover can diagnose.

Connecting two gate outputs directly onto one wire creates a short circuit.

The wire settles to Error (E, red) state when both drivers are active with opposite values.

The AI Signal Prover traces the conflicting drivers and highlights the root cause.

Fix: separate the outputs with an OR gate or use Controlled Buffers (tri-state).

Tip: If the wire is Error (red), use the "Why this value?" feature to diagnose.

1A0BDriverADriverBESharedBus
As it opens in the app, with live wire colors.
01Z floatingE conflict (dashed)

Open in the app

Every input combination, run through the simulator
ABSharedBus
000
01E
10E
111